2013年12月10日星期二

How to Set the Port of the SCUB/SCUN as the Upstream Port

Question:
Both Huawei SCUB and Huawei SCUN have four GE optical ports, which can function as upstream ports. How to set the GE optical port of the control board (SCUB/SCUN) as upstream ports when upstream transmission is not implemented by the GIU board?

Answer:
Switching to the upstream port of the SCUB is controlled by the electronic switch. At a time, only the upstream port of the GIU board or the port of the control board can be used for upstream transmission.
Note: In the case of the SCUB, make sure that the current configuration of the system is already saved before running the electro-switch command. After this command is run, the system will be reset.

A To set the port of the control board as the upstream port, run the electro-switch 0
location-0 command.
B To set the port of the GIU board as the upstream port, run the electro-switch 0
location-1 command.
C The SCUN can work with the Huawei EPON GIU upstream board. In this case, the SCUN equals an
upstream board in another GIU slot.

More information about the MA5600 series, please visit: http://www.huanetwork.com